Safety Products | Dorgard SmartSound

>Trade Name: Dorgard SmartSound

Fire Door Retainer

Email to a Friend Share this product page from Astroflame on Facebook Share this product page from Astroflame on Twitter Share this product page from Astroflame on Google+ Share this product page from Astroflame on LinkedIn Share this product page from Astroflame on Pinterest

View All Safety Products Download The Safety Product Brochure
Dorgard SmartSound In Hospitals
Fire Door Retainer
Dorgard SmartSound Install Image 1
Dorgard SmartSound Install Image 2
Dorgard SmartSound In Schools
Dorgard SmartSound In Care Homes
Dorgard SmartSound At The Office
full size product image from Astroflame


Dorgard SmartSound Product In Hospitals
Door Retainer
Dorgard SmartSound Installation 1
Dorgard SmartSound Installation 2
Dorgard SmartSound Product In Schools
Dorgard SmartSound Product In Care Homes
Dorgard SmartSound Product In The Office

> Quick Overview


TO ORDER & SPECIFY

Telephone Astroflame 01329 844 500



Email Astroflame sales@astroflame.com



PDF Data Sheets Download PDF Data Sheets



Sign Up for Updates & Offers

For in-stock items orders received before 2pm (Monday-Friday) are generally dispatched for delivery on the following working day (Monday-Friday).


> Product Description

Dorgard SmartSound is a wireless fire door retainer which holds fire doors open. The unit continually listens for the frequency of the alarm and once verified, will automatically release the door to close. It enables greater accessibility and complies with fire regulations.

The product offers three year's peace of mind with warranty, battery and service frequency. Suitable for environments that already have an automatic fire detection system installed:

> Technical information

Information
Power Two x LR14 C-size batteries (included)
Expected battery life Three years
Colour Black
Width 195mm
Height 205mm
Depth 45mm
Weight 700g
Activation SmartSound listening technology
Casing ABS plastic
Hold open positions Can hold the door at any angle
Maximum door size Power size 7 (max of 160kg and 1600mm width)
Audible warning Warns of door closing on fire or fault
Fire rating Suitable for up to 120 minute fire doors
Compliant to EN1155, EN1634, EMC Directive, Radio Equipment Directive, CE Marked
Suitable for Standard (category B) installations under BS7273-4 2015

> Product Availability

Available in a Black colour

Product Code Product Description Colour
AFDGRBLK Dorgard SmartSound Black

> To Order & Specify

Please contact us and quote the following - Quantity / Product Description / Product Code / Colour
Typical wording - 10 / Dorgard SmartSound / AFDGRBLK / Black

>> Tel: 01329 844 500 or >> Email: sales@astroflame.com


> Installation

We have technical representatives who provide assistance in the selection and specification of the products on this site and should be consulted for exact installation and product suitability. Ensure an early engagement with ourselves, designers, main contractor and specialist installers before any installation. Other trades and/or manufacturers may need to be consulted. For in-depth information, specification and technical advice please call our Head Office on tel 01329 844 500 or email sales@astroflame.com

> Maintenance

All interested parties, designer, specifier, main contractor and specialist installers should provide access to allow the fire stopping seals to be regularly inspected and maintained, as well as records kept of such maintenance at minimum periods of 12 months, as required by the Regulatory Reform Order, and repaired if necessary. Reference should be made to ASFP TGD 17 – Code of Practice for the Installation and Inspection of Fire Stopping.

> Competency

It is vital that those entrusted to design or install a fire stopping product have the necessary levels of competence to undertake the task professionally and thoroughly. The level of competency required will be commensurate with the expected complexity of the building. All designers must eliminate, reduce or control foreseeable risks that may arise during installation, construction or maintenance when preparing or modifying designs. Clients should ensure that the principal designer and principal contractor carry out their duties under CDM regulations. The ASFP foundation course in passive fire protection provides essential knowledge as part of demonstrating competency and understanding in this key fire protection specialism.

> Additional Notes

For further information on installation requirements please refer to the door manufacturer data to ensure the compatibility of this product, if in doubt please contact the technical team on: tel 01329 844 500 or email sales@astroflame.com

> Health and Safety

The product does not present any known health hazards during or after installation. Normal good industrial and personal hygiene practices should be observed. For further information on health and safety requirements please contact the technical team on: tel 01329 844 500 or email sales@astroflame.com

> Testimonial

Bromley School found that the Dorgard unit helped his school with easier accessibility, ventilation and compliance.

Since installing Dorgard we fully conform to fire regulations and there is much more space through the corridor so pupils can move about more easily. The fire doors are fully opened against the wall now and stay there. Dorgard makes life easier for everyone.

We now have a Dorgard on every fire door. Fireco has always provided a superb service, from the day I placed the order through to delivery. Our caretaker finds them straightforward to fit so installation causes no no disruption to the school day. I have recommended them to other colleagues and would recommend them to anybody.


> Data Sheet Downloads

Download and review the following available data sheets for this product.

Key Information:
  • PDS's are Product Data Sheets
  • SDS's are Safety Data Sheets
  • TDS's are Technical Data Sheets
  • INT's are Install Data Sheets
  • VID's are Video Files
  • DoP's are Declaration of Performance
  • CoC's are Certificate of Constancy of Performance
  • ETA's are European Technical Assessment Sheet
  • UL Documentation are UL - EU Certificate

> Delivery/Returns

For in-stock items orders received before 2pm (Monday-Friday) are generally dispatched for delivery on the following working day (Monday-Friday). All dates quoted for despatch are estimates only and are not guaranteed. We will endeavour to meet these dates but shall have no liability for any delay in despatch or delivery or any damage or loss occasioned thereby. We may deliver products pursuant to any order by instalments. If we are unable to deliver the goods for any reason,you will be contacted and you will not be obliged to pay for the goods which have not been delivered, you also have the option to cancel the goods that have been delivered, however we shall not be liable for any loss of income or profit which may have been caused by the delay or non delivery of goods.

For information about our returns policy please click here.

> Ask a Question

If you've got a question about this product or need some technical help get in touch with the Astroflame sales or technical team to discuss your requirements today. We are open Monday to Friday 8:00am to 5:30pm. You can always contact us on the following:

T: 01329 844 500

E: sales@astroflame.com

Web Page Last Modified: 12th February 2024

Data Sheets Downloads

or click "x" to close this box.

×