Fire Stop Products | Astro Batt

>Trade Name: Astro Batt

Fire Resistant Batt

Email to a Friend Share this product page from Astroflame on Facebook Share this product page from Astroflame on Twitter Share this product page from Astroflame on Google+ Share this product page from Astroflame on LinkedIn Share this product page from Astroflame on Pinterest

View All Fire Stopping Products Download The Fire Stopping Brochure
Astro Batt
Fire Resistant Batt in floors
Fire Resistant Batt cut to size
Fire Resistant Batt in walls
full size product image from Astroflame


Batt - fire boards
Fire Batt installed in floors
Fire Batts can be cut to your size requirements
Fire Batt installation in walls

> Quick Overview


TO ORDER & SPECIFY

Telephone Astroflame 01329 844 500



Email Astroflame sales@astroflame.com



PDF Data Sheets Download PDF Data Sheets



Sign Up for Updates & Offers

For in-stock items orders received before 2pm (Monday-Friday) are generally dispatched for delivery on the following working day (Monday-Friday).


> Product Description

CE Label Astro PFP FR Coating Product

Specifically designed for sealing around service penetrations in walls and floors, a single Astroflame board (50mm or 60mm thick) can provide high levels of fire integrity and insulation.

Tested in Block Wall, Concrete, Masonry, Plasterboard Partition and tested in Concrete Floors.

Offering up to 4 hours fire resistance in accordance with BS476: Part 20: 1987 and EN 1366-3 : 2009. Up to Rw 60dB sound reduction please refer to the Astroflame technical department.

Astroflame Boards consist of a stone fibre core coated on both sides with Astro Coat which transforms during a fire to prevent the passage of fire and smoke and the transfer of heat.

Astro Batt cut edges or joints should be coated with Astro coat or Astro mastic.

*For specific details please refer to the test certification.

Please note specific fire, acoustic & EI Ratings will vary depending on the thickness of batt used and the configuration, please contact us for confirmation.

> Properties & Specification

50mm Thickness Batt
Dimensions 1200mm x 600mm x 50mm
Stone Fibre Density 140Kg/m³
Coating Thickness 1mm Nominal, 2.2kg wet film coating
Fire Resistance/Insulation 4 hours - BS476 pt20/22; EN 1366-3, EI 120 & EN 13501-2
Acoustic Performance Acoustic Reduction up to 60dB please refer to the Astroflame technical department
Air Permeability 600Pa EN 1026 - 100Pa 1.8/1.4 m3/h/m2

60mm Thickness Batt
Dimensions 1200mm x 600mm x 60mm
Stone Fibre Density 160Kg/m³
Coating Thickness 1mm Nominal, 2.2kg wet film coating
Fire Resistance/Insulation 4 hours - BS476 pt20/22; EN 1366-3, EI 120 & EN 13501-2
Acoustic Performance Acoustic Reduction up to 60dB please refer to the Astroflame technical department
Air Permeability 600Pa EN 1026 - 100Pa 1.8/1.4 m3/h/m2

> Product Availability

Product Code Product Description Weight
AFB1200DC50 Astro Batt 600mm x 1200mm x 50mm: 140kgm3 density
AFB1200DC Astro Batt 600mm x 1200mm x 60mm: 160kgm3 density.

> To Order & Specify

Please contact us and quote the following information - Please quote- Quantity / Product Code / Product Description / Size
Typical wording- 20/ AFB1200DC50 / Astro Batt / 600mm x 1200mm x 50mm

>> Tel: 01329 844 500 or >> Email: sales@astroflame.com


> Installation

We have technical representatives who provide assistance in the selection and specification of the products on this site and should be consulted for exact installation and product suitability. Ensure an early engagement with ourselves, designers, main contractor and specialist installers before any installation. Other trades and/or manufacturers may need to be consulted. For in-depth information, specification and technical advice please call our Head Office on tel 01329 844 500 or email sales@astroflame.com

> Maintenance

All interested parties, designer, specifier, main contractor and specialist installers should provide access to allow the fire stopping seals to be regularly inspected and maintained, as well as records kept of such maintenance at minimum periods of 12 months, as required by the Regulatory Reform Order, and repaired if necessary. Reference should be made to ASFP TGD 17 – Code of Practice for the Installation and Inspection of Fire Stopping.

> Competency

It is vital that those entrusted to design or install a fire stopping product have the necessary levels of competence to undertake the task professionally and thoroughly. The level of competency required will be commensurate with the expected complexity of the building. All designers must eliminate, reduce or control foreseeable risks that may arise during installation, construction or maintenance when preparing or modifying designs. Clients should ensure that the principal designer and principal contractor carry out their duties under CDM regulations. The ASFP foundation course in passive fire protection provides essential knowledge as part of demonstrating competency and understanding in this key fire protection specialism.

> Additional Notes

Please refer to the ETA/UL-EU sheet for fields of application for this product. For further information on installation requirements please refer to the manufacturer of the services and the wall/floor specification to ensure the compatibility of this product, if in doubt please contact the technical team with services and wall/floor specification on: tel 01329 844 500 or email sales@astroflame.com

> Health and Safety

The product does not present any known health hazards during or after installation. Normal good industrial and personal hygiene practices should be observed. For further information on health and safety requirements please contact the technical team on: tel 01329 844 500 or email sales@astroflame.com


> Data Sheet Downloads

Download and review the following available data sheets for this product.

Key Information:
  • PDS's are Product Data Sheets
  • SDS's are Safety Data Sheets
  • TDS's are Technical Data Sheets
  • INT's are Install Data Sheets
  • VID's are Video Files
  • DoP's are Declaration of Performance
  • CoC's are Certificate of Constancy of Performance
  • ETA's are European Technical Assessment Sheet
  • CF's are Certifire Certificates
  • UL Documentation are UL - EU Certificate

> Delivery/Returns

For in-stock items orders received before 2pm (Monday-Friday) are generally dispatched for delivery on the following working day (Monday-Friday). All dates quoted for despatch are estimates only and are not guaranteed. We will endeavour to meet these dates but shall have no liability for any delay in despatch or delivery or any damage or loss occasioned thereby. We may deliver products pursuant to any order by instalments. If we are unable to deliver the goods for any reason,you will be contacted and you will not be obliged to pay for the goods which have not been delivered, you also have the option to cancel the goods that have been delivered, however we shall not be liable for any loss of income or profit which may have been caused by the delay or non delivery of goods.

For information about our returns policy please click here.

> Ask a Question

If you've got a question about this product or need some technical help get in touch with the Astroflame sales or technical team to discuss your requirements today. We are open Monday to Friday 8:00am to 5:30pm. You can always contact us on the following:

T: 01329 844 500

E: sales@astroflame.com

Web Page Last Modified: 12th February 2024