Fire Stop Products | Astro PFP FR Pipe Wrap

>Trade Name: Astro PFP FR Pipe Wrap

Intumescent Pipe Wraps CE Marked

Email to a Friend Share this product page from Astroflame on Facebook Share this product page from Astroflame on Twitter Share this product page from Astroflame on Google+ Share this product page from Astroflame on LinkedIn Share this product page from Astroflame on Pinterest

View All Fire Stopping Products Download The Fire Stopping Brochure
Astro PFP FR Pipe Wrap
Astro PFP FR Pipe Wrap Product
Intumescent Pipe Wraps CE Marked
Intumescent Pipe Wraps
Astro PFP FR Pipe Wrap
full size product image from Astroflame


PFP FR Pipe Wrap
PFP FR Pipe Wrap Product
Pipe Wraps CE Marked
Wraps CE Marked
Pipe Wraps 3D Visual

> Quick Overview


TO ORDER & SPECIFY

Telephone Astroflame 01329 844 500



Email Astroflame sales@astroflame.com



PDF Data Sheets Download PDF Data Sheets



Sign Up for Updates & Offers

For in-stock items orders received before 2pm (Monday-Friday) are generally dispatched for delivery on the following working day (Monday-Friday).


> Product Description

CE Astro PFP FR Pipe Wrap Marking

The Astro PFP FR Pipe Wrap is designed to maintain the fire resistance of fire separating walls and floors when these are breached by plastic pipes, conduits or metal pipes with continuous combustible insulation, and may be used in drywalls, masonry or concrete walls and concrete floors.

Each pipe wrap consists of a graphite based reactive intumescent strip, which reacts to heat and closes the opening left by the softening plastic pipe or pipe insulation in a fire. The pipe wrap is installed completely around the pipes or insulation and secured with the self adhesive tab. The annular space around the pipe wrap is sealed with Astro PFP FR EX Mortar or Astro PFP FR Boards.

Sizes and Intended Use:

Product Code Size Intended Use
AFPFPPW55 Astro PFP FR Pipe Wrap 55mm Plastic pipes & conduits ≤ ∅55mm
AFPFPPW82 Astro PFP FR Pipe Wrap 82mm Plastic pipes & conduits ≤ ∅82mm
AFPFPPW110 Astro PFP FR Pipe Wrap 110mm Plastic pipes & conduits ≤ ∅110mm
AFPFPPW125 Astro PFP FR Pipe Wrap 125mm Plastic pipes ≤ ∅125mm
AFPFPPW160 Astro PFP FR Pipe Wrap 160mm Plastic pipes ≤ ∅160mm
AFPFPPW200 Astro PFP FR Pipe Wrap 200mm Plastic pipes ≤ ∅200mm
AFPFPPW250 Astro PFP FR Pipe Wrap 250mm Plastic pipes ≤ ∅250mm
AFPFPPW315 Astro PFP FR Pipe Wrap 315mm Plastic pipes ≤ ∅315mm

> Technical Data

Technical Approval ETAG 026-2
Durability according to ETAG 026-2 Z2 intended for use in internal conditions with humidity classes other than Z1, excluding temperatures below 0°C.
Conditioning procedure EN 13238:2010
Expansion ratio 28:1
Expansion pressure 55 N
Colour Anthracite
Graphite weight 1.3 kg/m2 per mm thickness
Graphite density 1300 kg/m3
Normal expansion time Less than 10 minutes
Minimum expansion temperature 150°C
Storage Store in temperatures between 5°C and 30°C
Life Under normal conditions; 30 years +

> Product Availability

Product Code Product Description Size
AFPFPPW55 Astro PFP FR Pipe Wrap 55mm 55mm
AFPFPPW82 Astro PFP FR Pipe Wrap 82mm 82mm
AFPFPPW110 Astro PFP FR Pipe Wrap 110mm 110mm
AFPFPPW125 Astro PFP FR Pipe Wrap 125mm 125mm
AFPFPPW160 Astro PFP FR Pipe Wrap 160mm 160mm
AFPFPPW200 Astro PFP FR Pipe Wrap 200mm 200mm
AFPFPPW250 Astro PFP FR Pipe Wrap 250mm 250mm
AFPFPPW315 Astro PFP FR Pipe Wrap 315mm 315mm

> To Order & Specify

Please contact us and quote the following information - Please quote- Quantity / Trade name / Product Ref / Size
Typical example:- 25 / AFPFPPW55 / Astro PFP FR Pipe Wrap 55mm / 55mm

>> Tel: 01329 844 500 or >> Email: sales@astroflame.com


> Installation

We have technical representatives who provide assistance in the selection and specification of the products on this site and should be consulted for exact installation and product suitability. Ensure an early engagement with ourselves, designers, main contractor and specialist installers before any installation. Other trades and/or manufacturers may need to be consulted. For in-depth information, specification and technical advice please call our Head Office on tel 01329 844 500 or email sales@astroflame.com

> Maintenance

All interested parties, designer, specifier, main contractor and specialist installers should provide access to allow the fire stopping seals to be regularly inspected and maintained, as well as records kept of such maintenance at minimum periods of 12 months, as required by the Regulatory Reform Order, and repaired if necessary. Reference should be made to ASFP TGD 17 – Code of Practice for the Installation and Inspection of Fire Stopping.

> Competency

It is vital that those entrusted to design or install a fire stopping product have the necessary levels of competence to undertake the task professionally and thoroughly. The level of competency required will be commensurate with the expected complexity of the building. All designers must eliminate, reduce or control foreseeable risks that may arise during installation, construction or maintenance when preparing or modifying designs. Clients should ensure that the principal designer and principal contractor carry out their duties under CDM regulations. The ASFP foundation course in passive fire protection provides essential knowledge as part of demonstrating competency and understanding in this key fire protection specialism.

> Additional Notes

Please refer to the ETA sheet for fields of application for this product. For further information on installation requirements please refer to the pipe manufacturer data and wall specification to ensure the compatibility of this product, if in doubt please contact the technical team with services and wall specification on: tel 01329 844 500 or email sales@astroflame.com

> Health and Safety

The product does not present any known health hazards during or after installation. Normal good industrial and personal hygiene practices should be observed. For further information on health and safety requirements please contact the technical team on: tel 01329 844 500 or email sales@astroflame.com


> Data Sheet Downloads

Download and review the following available data sheets for this product.

Key Information:
  • PDS's are Product Data Sheets
  • SDS's are Safety Data Sheets
  • TDS's are Technical Data Sheets
  • INT's are Install Data Sheets
  • VID's are Video Files
  • DoP's are Declaration of Performance
  • CoC's are Certificate of Constancy of Performance
  • ETA's are European Technical Assessment Sheet
  • UL Documentation are UL - EU Certificate

> Delivery/Returns

For in-stock items orders received before 2pm (Monday-Friday) are generally dispatched for delivery on the following working day (Monday-Friday). All dates quoted for despatch are estimates only and are not guaranteed. We will endeavour to meet these dates but shall have no liability for any delay in despatch or delivery or any damage or loss occasioned thereby. We may deliver products pursuant to any order by instalments. If we are unable to deliver the goods for any reason,you will be contacted and you will not be obliged to pay for the goods which have not been delivered, you also have the option to cancel the goods that have been delivered, however we shall not be liable for any loss of income or profit which may have been caused by the delay or non delivery of goods.

For information about our returns policy please click here.

> Ask a Question

If you've got a question about this product or need some technical help get in touch with the Astroflame sales or technical team to discuss your requirements today. We are open Monday to Friday 8:00am to 5:30pm. You can always contact us on the following:

T: 01329 844 500

E: sales@astroflame.com

Web Page Last Modified: 12th February 2024

Data Sheets Downloads

or click "x" to close this box.

×