The Astro PFP FR Pipe Wrap is designed to maintain the fire resistance of fire separating walls and floors when these are breached by plastic pipes, conduits or metal pipes with continuous combustible insulation, and may be used in drywalls, masonry or concrete walls and concrete floors.
Each pipe wrap consists of a graphite based reactive intumescent strip, which reacts to heat and closes the opening left by the softening plastic pipe or pipe insulation in a fire. The pipe wrap is installed completely around the pipes or insulation and secured with the self adhesive tab. The annular space around the pipe wrap is sealed with Astro PFP FR EX Mortar or Astro PFP FR Boards.
Sizes and Intended Use:
Product Code | Size | Intended Use |
AFPFPPW55 | Astro PFP FR Pipe Wrap 55mm | Plastic pipes & conduits ≤ ∅55mm |
AFPFPPW82 | Astro PFP FR Pipe Wrap 82mm | Plastic pipes & conduits ≤ ∅82mm |
AFPFPPW110 | Astro PFP FR Pipe Wrap 110mm | Plastic pipes & conduits ≤ ∅110mm |
AFPFPPW125 | Astro PFP FR Pipe Wrap 125mm | Plastic pipes ≤ ∅125mm |
AFPFPPW160 | Astro PFP FR Pipe Wrap 160mm | Plastic pipes ≤ ∅160mm |
AFPFPPW200 | Astro PFP FR Pipe Wrap 200mm | Plastic pipes ≤ ∅200mm |
AFPFPPW250 | Astro PFP FR Pipe Wrap 250mm | Plastic pipes ≤ ∅250mm |
AFPFPPW315 | Astro PFP FR Pipe Wrap 315mm | Plastic pipes ≤ ∅315mm |
Technical Approval | ETAG 026-2 |
Durability according to ETAG 026-2 | Z2 intended for use in internal conditions with humidity classes other than Z1, excluding temperatures below 0°C. |
Conditioning procedure | EN 13238:2010 |
Expansion ratio | 28:1 |
Expansion pressure | 55 N |
Colour | Anthracite |
Graphite weight | 1.3 kg/m2 per mm thickness |
Graphite density | 1300 kg/m3 |
Normal expansion time | Less than 10 minutes |
Minimum expansion temperature | 150°C |
Storage | Store in temperatures between 5°C and 30°C |
Life | Under normal conditions; 30 years + |
Product Code | Product Description | Size |
AFPFPPW55 | Astro PFP FR Pipe Wrap 55mm | 55mm |
AFPFPPW82 | Astro PFP FR Pipe Wrap 82mm | 82mm |
AFPFPPW110 | Astro PFP FR Pipe Wrap 110mm | 110mm |
AFPFPPW125 | Astro PFP FR Pipe Wrap 125mm | 125mm |
AFPFPPW160 | Astro PFP FR Pipe Wrap 160mm | 160mm |
AFPFPPW200 | Astro PFP FR Pipe Wrap 200mm | 200mm |
AFPFPPW250 | Astro PFP FR Pipe Wrap 250mm | 250mm |
AFPFPPW315 | Astro PFP FR Pipe Wrap 315mm | 315mm |
Please contact us and quote the following information - Please quote- Quantity / Trade name / Product Ref / Size
Typical example:- 25 / AFPFPPW55 / Astro PFP FR Pipe Wrap 55mm / 55mm
>> Tel: 01329 844 500 or >> Email: sales@astroflame.com
We have technical representatives who provide assistance in the selection and specification of the products on this site and should be consulted for exact installation and product suitability. Ensure an early engagement with ourselves, designers, main contractor and specialist installers before any installation. Other trades and/or manufacturers may need to be consulted. For in-depth information, specification and technical advice please call our Head Office on tel 01329 844 500 or email sales@astroflame.com
All interested parties, designer, specifier, main contractor and specialist installers should provide access to allow the fire stopping seals to be regularly inspected and maintained, as well as records kept of such maintenance at minimum periods of 12 months, as required by the Regulatory Reform Order, and repaired if necessary. Reference should be made to ASFP TGD 17 – Code of Practice for the Installation and Inspection of Fire Stopping.
It is vital that those entrusted to design or install a fire stopping product have the necessary levels of competence to undertake the task professionally and thoroughly. The level of competency required will be commensurate with the expected complexity of the building. All designers must eliminate, reduce or control foreseeable risks that may arise during installation, construction or maintenance when preparing or modifying designs. Clients should ensure that the principal designer and principal contractor carry out their duties under CDM regulations. The ASFP foundation course in passive fire protection provides essential knowledge as part of demonstrating competency and understanding in this key fire protection specialism.
Please refer to the ETA sheet for fields of application for this product. For further information on installation requirements please refer to the pipe manufacturer data and wall specification to ensure the compatibility of this product, if in doubt please contact the technical team with services and wall specification on: tel 01329 844 500 or email sales@astroflame.com
The product does not present any known health hazards during or after installation. Normal good industrial and personal hygiene practices should be observed. For further information on health and safety requirements please contact the technical team on: tel 01329 844 500 or email sales@astroflame.com
Download and review the following available data sheets for this product.
For in-stock items orders received before 2pm (Monday-Friday) are generally dispatched for delivery on the following working day (Monday-Friday). All dates quoted for despatch are estimates only and are not guaranteed. We will endeavour to meet these dates but shall have no liability for any delay in despatch or delivery or any damage or loss occasioned thereby. We may deliver products pursuant to any order by instalments. If we are unable to deliver the goods for any reason,you will be contacted and you will not be obliged to pay for the goods which have not been delivered, you also have the option to cancel the goods that have been delivered, however we shall not be liable for any loss of income or profit which may have been caused by the delay or non delivery of goods.
For information about our returns policy please click here.
If you've got a question about this product or need some technical help get in touch with the Astroflame sales or technical team to discuss your requirements today. We are open Monday to Friday 8:00am to 5:30pm. You can always contact us on the following:
Web Page Last Modified: 3rd July 2024